9W/18W/22W/30W

Features

  • Energy saving with low power consumption
  • Perfect retrofit traditional lamps with no change on dimensions
  • Smooth operation even at low temperatures
  • No mercury and hazardous substances
  • Selectable CCT via dip-switch
  • Inventory cost saving
  • Type A/B is for direct retrofit of magnetic ballast circuit
  • Full glass body
  • Voltage: 220-240Vac, 50/60Hz, Power Factor: 0.9
  • High efficacy up to 120lm/W
  • Good color rendition, Ra ≥80

Diagrams

Dimensions
Circuits

Standards

CE
ROHS
50_60Hz
Not for EL
IP20

Applications

Home
Home
Office
Office
Shopping mall
Shopping mall
Hotel
Hotel
Supermarket
Supermarket
Restaurant
Restaurant
Parking
Parking
School
School
Warehouse
Warehouse
Factory
Factory
Hospital
Hospital
Gallery
Gallery
Museum
Museum
Airport
Airport
Station
Station

Technical Data

Type of Light Source
Lighting Technology Used LED
Non-directional or Directional [NDLS/DLS] NDLS
Mains or Non-mains [MLS/NMLS] MLS
Connected Light Source No
Color tunable light source No
Envelop [No/Second/Non-Clear] No
High Luminance Light Source No
Anti-glare Shield No
Electrical
Rated Wattage [W] 9W / 18W / 22W / 30W
On-mode Power [W] 9W / 18W / 22W / 30W
Standby Power [W] N/A
Networked Standby Power [W] N/A
Rated Voltage [V/Hz] 220-240Vac, 50/60Hz
Power Factor @230V 0.85 / 0.9 / 0.9 / 09
Input Current [mA] @230V 46 / 87 / 106 / 145
Model
LED F9T8/8XX/G/600/3CCT 9W
LED F18T8/8XX/G/1200/3CCT 18W
LED F22T8/8XX/G/1500/3CCT 22W
LED F30T8/8XX/G/1800/3CCT 30W
Luminous Flux [lm]
9W 900lm @3000K
990lm @4000K
990lm @6500K
18W 1900lm @3000K
1980lm @4000K
1980lm @6500K
22W 2320lm @3000K
2420lm @4000K
2420lm @6500K
30W 3300lm @3000K
3600lm @4000K
3600lm @6500K
Performance
SDCM <6
Chromaticity coordinates [x, y] 0.44, 0.403@3000K / 0.38, 0.38@4000K / 0.312, 0.335@6500K
Efficacy [lm/W] 100-120
Color Rendering Index [Ra] ≥80
R9 colour rendering index value 2
Beam Angle [°] 280
Rated Life, Ta@25°C [hrs] 40,000
Survival Factor 0.9
Lumen Maintenance Factor 0.96
Number of Switching Cycles Before Failure >15,000
Starting Time [S] <0.5
Warm Up Time [S] <2
Premature Failure At 1000hrs <5%
Displacement Factor [cosØ] 0.5 / 0.7 / 0.7 / 0.9
Flicker Metric [Pst LM] 1
Stroboscopic Effect Metric [SVM] 0.4
Mechanical
Diameter D [mm] Φ29
Length L1 [mm] 588 / 1198 / 1500 / 1764
Length L2 [mm] 602 / 1212 / 1513 / 1778
Base G13
Material Glass
Standard Compliance
CE-LVD EN62776
CE-EMC EN55015, EN61547, EN61000-3-2, EN61000-3-3
CE-EMF EN62493
Environment RoHS
Mercury Content [mg] 0.0
Energy Class E
Other
Dimmable [Yes/Only with specific dimmers/No] No
Operation Temperature -20°C ~ 50°C
Storage Temperature -10°C ~ 30°C
Energy Consumption in on-mode [kWh/1000h] 9kWh / 18kWh / 22kWh / 30kWh