LED T5 AC HPF

8W/12W/14W/16W/20W/25W

Features

  • Energy saving with low power consumption
  • High efficacy up to 150lm/W
  • Smooth operation even at low temperatures
  • No mercury and hazardous substances
  • Full glass body
  • Voltage: 100-277Vac, 50/60Hz, Power Factor: 0.9
  • Good color rendition, Ra ≥80

Diagrams

Dimensions
Circuits

Standards

CE
ROHS
50_60Hz
Not for EL
IP20

Applications

Home
Home
Office
Office
Shopping mall
Shopping mall
Hotel
Hotel
Supermarket
Supermarket
Restaurant
Restaurant
Parking
Parking
School
School
Warehouse
Warehouse
Factory
Factory
Hospital
Hospital
Gallery
Gallery
Museum
Museum
Airport
Airport
Station
Station

Technical Data

Type of Light Source
Lighting Technology Used LED
Non-directional or Directional [NDLS/DLS] NDLS
Mains or Non-mains [MLS/NMLS] MLS
Connected Light Source No
Color tunable light source No
Envelop [No/Second/Non-Clear] No
High Luminance Light Source No
Anti-glare Shield No
Electrical
Rated Wattage [W] 8W / 12W / 14W / 16W / 20W / 25W
On-mode Power [W] 8W / 12W / 14W / 16W / 20W / 25W
Standby Power [W] N/A
Networked Standby Power [W] N/A
Rated Voltage [V/Hz] 100-277Vac, 50/60Hz
Power Factor @230V 0.85 / 0.85 / 0.85 / 0.85 / 0.9 / 0.9
Input Current [mA] @230V 41 / 61 / 72 / 82 / 97 / 121
Model
LED F8T5/AC/8XX/600/L 8W
LED F14T5/AC/8XX/600/L 14W
LED F12T5/AC/8XX/900/L 12W
LED F20T5/AC/8XX/900/L 20W
LED F16T5/AC/8XX/1200/L 16W
LED F25T5/AC/8XX/1200/L 25W
LED F20T5/AC/8XX/1500/L 20W
LED F25T5/AC/8XX/1500/L 25W
Luminous Flux [lm]
8W 1160lm @3000K
1180lm @4000K
1200lm @6500K
12W 1740lm @3000K
1770lm @4000K
1800lm @6500K
14W 2030lm @3000K
2065lm @4000K
2100lm @6500K
16W 2320lm @3000K
2370lm @4000K
2400lm @6500K
20W 2900lm @3000K
2950lm @4000K
3000lm @6500K
25W 3630lm @3000K
3690lm @4000K
3750lm @6500K
Performance
SDCM <6
Chromaticity coordinates [x, y] 0.44, 0.403@3000K
0.38,0.38@4000K
0.312, 0.335@6500K
Efficacy [lm/W] 145-150
Color Rendering Index [Ra] ≥80
R9 colour rendering index value 2
Beam Angle [°] 270
Rated Life, Ta@25°C [hrs] 40,000
Survival Factor 0.9
Lumen Maintenance Factor 0.96
Number of Switching Cycles Before Failure >15,000
Starting Time [S] <0.5
Warm Up Time [S] <2
Premature Failure At 1000hrs <5%
Displacement Factor [cosØ] 0.5 - 0.9
Flicker Metric [Pst LM] 1
Stroboscopic Effect Metric [SVM] 0.4
Mechanical
Diameter D [mm] Φ16
Length L1 [mm] 549 (8W,14W) / 849 (12W,20W) / 1149 (16W,25W) / 1449 (20W,25W)
Length L2 [mm] 563 (8W,14W) / 863 (12W,20W) / 1163 (16W,25W) / 1463 (20W,25W)
Base G5
Material Glass
Standard Compliance
CE-LVD EN62776
CE-EMC EN55015, EN61547, EN61000-3-2, EN61000-3-3
CE-EMF EN62493
Environment RoHS
Mercury Content [mg] 0.0
Energy Class D
Other
Dimmable [Yes/Only with specific dimmers/No] No
Operation Temperature -20°C ~ 45°C
Storage Temperature -10°C ~ 30°C
Energy Consumption in on-mode [kWh/1000h] 8kWh / 12kWh / 14kWh / 16kWh / 20kWh / 25kWh