語言简体中文
Features
Diagrams
Standards
Applications
Parking
Garden
Warehouse
Station
Electrical | |
Rated Wattage [W] | 7W / 14W |
Rated Voltage [V/Hz] | 100-240V, 50/60Hz |
Power Factor @230V | 0.9 |
Input Current [mA] @230V | 34 / 68 |
LED | SMD |
Model | |
NB101E-7W/8XX | 7W |
NB101E-7W/8XX-S | 7W (2 Step Dimming Sensing) |
NB101E-7W/8XX-EM | 7W (3 Hours Emergency) |
NB101E-7W/8XX-S-EM | 7W (Sensing & Emergency) |
NB101E-14W/8XX | 14W |
NB101E-14W/8XX-S | 14W (2 Step Dimming Sensing) |
NB101E-14W/8XX-EM | 14W (3 Hours Emergency) |
NB101E-14W/8XX-S-EM | 14W (Sensing & Emergency) |
Luminous Flux [lm] | |
7W / 7W-S | 780lm @3000K |
810lm @4000K | |
840lm @6500K | |
7W-EM / 7W-S-EM | 710lm @3000K |
740lm @4000K | |
770lm @6500K | |
14W / 14W-S | 1560lm @3000K |
1620lm @4000K | |
1680lm @6500K | |
14W-EM / 14W-S-EM | 1420lm @3000K |
1480lm @4000K | |
1540lm @6500K | |
Performance | |
SDCM | <6 |
Efficacy [lm/W] | 101-120 |
Color Rendering Index [Ra] | ≥80 |
Beam Angle [°] | 120 |
Rated Life, Ta@25°C [hrs] | 50,000 |
Lamp Survival Factor at 6000hrs | >0.9 |
Lumen Maintenance at 6000hrs | >0.8 |
Number of Switching Cycles Before Failure | >15,000 |
Starting Time [S] | <0.5 |
Warm Up Time [S] | <2 |
Premature Failure At 1000hrs | <5% |
Emergency Output | 30% |
Emergency Duration [hrs] | 3 |
Charge Time [hrs] | 12 |
Mechanical | |
Length L [mm] | 390 |
Width W [mm] | 110 |
Height H [mm] | 90 |
Material | Body : Die cast aluminum with matt white finish |
Diffuser: Clear prismatic polycarbonate | |
Sensor type | Microwave 5.8 GHz |
Sensor distance [m] | 1-8 |
Standby time [s] | 10-300 |
Standby power [W] | 0.9 |
Sensor detection angle [°] | 120 |
Standard Compliance | |
CE-LVD | EN60598-1, EN60598-2-2, EN60598-2-22 |
CE-EMC | EN55015, EN61547, EN61000-3-2, EN61000-3-3 |
CE-EMF | EN62493 |
Mercury Content [mg] | 0.0 |
Electrical Class | I |
Other | |
Dimmable [Y/N] | Y |
Operation Temperature | -20°C ~ 40°C |
Storage Temperature | -30°C ~ 60°C |